Release notes
This page contains list of changes, fixes and new features in FEM-Design 25
Version 25.01.001
Released: 30th of Sept 2026
Added:
General
- Partial implementation of 2nd generation of Eurocode.
- Models can now be saved in SAF format.
- New vehicle loads are added to the traffic load library (FLM2, FLM3 and FLM4 loads for all annexes, DK LM3 KL 10 - 500 loads and DK LM3 Fladelast for Dannish annex).
- The new Convert function allows all structural elements and solids, including IFC-imported objects, to be converted into drawing regions.
- A warning message is now displayed for the most critical graphics engine errors.
- IFC import feedback has been improved by displaying only elements with warnings or errors.
- The shear center and axes are now visible in the detailed results for cross-sections.
Parametric model module
- An extended set of operators is now available between parameters (including square, power, absolute, sin/cos, deg/rad, min/max, and more).
- In Parametrization mode, all loads are now enabled by default - eliminating the need to manually activate their layers.
API
- Support for "Export reactions as loads" is now included.
- Support for footfall configuration in the calculation is now included.
- Configuration for orthotropic timber panel calculation parameters was missing.
- It now supports an option in auto design to honour the supplied cross-section order instead of sorting by area.
License system
- Dedicated "License not found" dialogs are now available for the web-based license system.
Modified:
- MathCad 15 export has been removed from the File... menu of the Detailed result windows.
- Autocad connection has been updated to RealDWG 2026.
- We have made major cleanup in the graphics engine. From now on, we do not expect any more crashes from this component, unless they originate from the graphics driver, which is outside our control. Gfx problems (such as running out of GPU memory) should only cause the graphics engine to shut down, rather than the entire application (the application will stop rendering), You will be able to save your work and restart the program.
- The “Setup Wizard” text has been removed from the installed product name in the Windows Apps & Features list.
- The web-based license system logout has been moved to a more visible location in Command Center.
Fixed:
RC bar design
- The API contained a typo in the attribute name arBarSpacing_BarSpacingMin.
- For columns, the normal force-dependent minimum reinforcement evaluation was not displayed correctly in the detailed results.
- A warning message is now displayed if some longitudinal reinforcing bars in the examined beam cross-section are not enclosed by stirrups
- It was not possible to modify the diameter of a stirrup in the Manual design.
- German NA: The amount of the minimum longitudinal reinforcement for columns is now calculated using the correct coefficient of 0.15.
- The program could crash when saving with the RC bar manual design window open.
- Changing properties in the RC bar reinforcement macro caused the program to crash in some cases.
- During the torsion check of reinforced concrete bars, the wall thickness of the perforated cross-section was not taken into account in the calculation of t,ef.
- German NA: The coefficient in the z = 0.9 · d formula is now displayed correctly in the detailed results for the minimum and maximum reinforcement checks.
RC shell design
- The shear reinforcement label was not visible.
- For RC bar section and RC wall buckling utilization, M.Rd and N.Rd are calculated more precisely.
Masonry design
- 2/E1 was not considered for masonry walls.
Parametric model
- The Input Wizard allowed invalid parameter values to be entered and locked them.
- The program could crash when using parametric shape for isolated foundation and then closing the panel.
- Defining sections using the Parametric shape function could cause a crash later in certain cases.
User interface
- The program could crash when loading a file (by Settings/Load button in the material dialog) containing materials that were no longer available in the library.
- Edge connection library items from models created in earlier FEM-Design versions did not work correctly in certain special cases.
- Multiple adjacent separators in vertical toolbars were displayed incorrectly.
- The program allowed the current drawing layer to be deleted when selected outside the Layer panel, which could cause a crash or other issues later,
- The tooltip for "add used type to library" was missing.